The touch screen computer dual-control smoke density tester for building materials is developed according to the technical conditions specified in the national standard GB/T8627-2007 “Smoke Density Test Method for the Burning or Decomposition of Building Materials”. It is suitable for static burning of building materials and their products and other materials. Determination of smoke production.
Application
The touch screen computer dual-control smoke density tester for building materials is developed according to the technical conditions specified in the national standard GB/T8627-2007 “Smoke Density Test Method for the Burning or Decomposition of Building Materials”. It is suitable for static burning of building materials and their products and other materials. Determination of smoke production.
Standard
GB/T8627-2007 ASTM D2843
Technical parameters
12 Automatic timing, automatic ignition, automatic smoke exhaust; the luminous flux can be linearly corrected and tested in stages, which improves the accuracy of the data;
1) Size: 5 inches, the effective display size is 11cm long and 6.28cm wide;
2) Resolution: 800*480
3) Communication interface RS232, 3.3V CMOS or TTL, serial port
4) Storage capacity: 1G
5) Using pure hardware FPGA to drive the display, “zero” startup time, and it can run after power-on
6) M3+FPGA architecture is adopted, M3 is responsible for instruction analysis, FPGA focuses on TFT display, and the main controller adopts low-energy processors and automatically enters energy-saving mode
Working environment
1. Ambient temperature |
0℃-40℃; |
2. Relative humidity |
≤85% |
3. Supply voltage and power |
220V±10%, 50HZ, 100W; |
4. Gas pressure |
0-0.3MPa (adjustable); |
5. Environment and test requirements |
When the instrument is working, it should be avoided that strong light is directly irradiated or reflected on the instrument; after 90 minutes of the test, the gas source should be turned off to cool the instrument for 15 minutes. |
6. Ambient air flow |
no forced air flow phenomenon in working state; |
7. The instrument should be placed in a fume hood for testing; |
Structure
Divided into two parts: smoke box and control;
Smoke box part: On the left and right side panels of the smoke box, there are power switches, safety signs switches (backlight switches), gas regulators, and switches for controlling exhaust fans (fan switches).
Features
© Dongguan Zhongli Instrument Technology Co., Ltd.
Leave your inquiry, we will provide you with quality products and services!
Please fill out the form below to request a quote or to request more information about us. please be as detailed as possible in your message, and we will get back to you as soon as possible with a response. we’re ready to start working on your new project, contact us now to get started.