ZL-3001A-2 No Rotor Rheometer Rubber Rheometer

Products

ZL-3001A-2 No Rotor Rheometer Rubber Rheometer

It adopts single-chip microcomputer control, which includes: host, temperature measurement, temperature control, data acquisition and processing, sensors and electrical chains and other components. The measurement and temperature control circuit is composed of a temperature controller, a platinum resistor, and a heater, which can automatically track changes in the grid and ambient temperature, and automatically correct PID parameters to achieve rapid and accurate temperature control. The data acquisition system and the electromechanical interlock complete the automatic detection of the torque signal during the rubber vulcanization process, and the automatic real-time display of the temperature and the set value. After the vulcanization is completed, it will automatically process, calculate, and print the vulcanization curve and process parameters. Display vulcanization time, vulcanization power torch.

Features:

It adopts single-chip microcomputer control, which includes: host, temperature measurement, temperature control, data acquisition and processing, sensors and electrical chains and other components. The measurement and temperature control circuit is composed of a temperature controller, a platinum resistor, and a heater, which can automatically track changes in the grid and ambient temperature, and automatically correct PID parameters to achieve rapid and accurate temperature control. The data acquisition system and the electromechanical interlock complete the automatic detection of the torque signal during the rubber vulcanization process, and the automatic real-time display of the temperature and the set value. After the vulcanization is completed, it will automatically process, calculate, and print the vulcanization curve and process parameters. Display vulcanization time, vulcanization power torch.

 

Comply With the Standard:

ASTM D5289 , ISO6502 , GB/T 16584

 

The Test Patterns Are:

1: The temperature curve of the upper and lower molds,

2: S’ Curing Torque Curve

3: S” viscoelastic torque curve

4: S* full torque curve

5: tanδ viscoelastic ratio curve

6: δ phase angle curve

 

Features

  1. The test time can be changed arbitrarily in the middle of the test
  2. 2. The test stops and the mold is automatically opened
  3. 3. All graphics can be set in different units (Ib-in kg-cm N-m dN-m)
  4. 4. The software supports complex Chinese, simplified Chinese, and English
  5. 5. Easy to operate, users can automatically test and save automatically without touching the computer
  6. 6. Each control interface includes curves, coordinates, and background colors can be set freely
  7. 7. The existing vulcanization curves can be compared with the reproducibility or difference at the same time or separately, and different colors can be set for each curve to facilitate comparison
  8. The test data has a variety of query functions, which can be searched according to time, date, rubber name, shift, operator, test temperature, and other test conditions
  9. The test data is stored in the form of a database, with multiple data export methods, export to, PDF, EXCEL and other document functions
  10. It has the upper and lower limit qualified values on the set report, and the software automatically judges whether it is qualified
  11. Various graphics can be printed on a report at the same time
  12. 1 Software and hardware automatic detection function, easy maintenance and repair
  13. 13. The number of data sampling is high, and no important data will be missed
  14. 14. High-precision temperature control system to ensure stability and temperature recovery speed
  15. 15. The fixed eccentric wheel structure is adopted to provide a very stable shearing angle and ensure the accuracy of the test
  16. 16. The high-precision torque sensor is installed close to the upper mold, and the upper mold cavity measures the torque, and the torque value is accurate and stable

 

Technical Parameters:

1. Temperature Control

 Computer online control. PID SSR

2. Control Range

 Room temperature – 200 ℃ computer setting

3. Minimum Display

 0.1°C

4. Temperature Error

 ±0.3℃

5. Heating Rate

 30°C to 180°C less than 8min

6. Torque Range

  0~10 N.m  (5 N.M and 20N.M Option)

7. Minimum Torque Reading

 0.001NM

8. Swing Angle

 ±0.5°C, ±1°C, ±2°C (standard angle 1 degree)

9. Oscillating Frequency

 100r/min (1.66HZ)

10. Air Pressure

 4KG, customer prepared

11. Communication Method

 COM port

12. Power Supply

 AC220V 50/60HZ 5A