ZL-2728 power frequency partial discharge tester is a comprehensive measurement equipment suitable for partial discharge and withstand voltage testing of high-voltage insulation materials, motor stator turns and coils, high-voltage isolation integrated circuits, semiconductor high-voltage switches and other devices. It can achieve 0.1 Withstand voltage test and partial discharge test in the kV~10kV range.
Product Description:
ZL-2728 power frequency partial discharge tester is a comprehensive measurement equipment suitable for partial discharge and withstand voltage testing of high-voltage insulation materials, motor stator turns and coils, high-voltage isolation integrated circuits, semiconductor high-voltage switches and other devices. It can achieve 0.1 Withstand voltage test and partial discharge test in the kV~10kV range.
The partial discharge tester adopts the test sample series coupling measurement mode. The test method complies with the general partial discharge measurement standard GB/T 7354-2018 (IEC60270:2000), and also complies with the partial discharge measurement standards of specific devices, such as the optical isolator safety standard ( IEC60747-5-5), digital isolator safety standard (IEC60747-17), low-voltage equipment safety standard (IEC60664-1), semiconductor switch component standard (IEC60747-15), etc.; has sine wave output waveform, multiple measurement conditions With the qualification judgment function, users can flexibly combine it according to their needs to achieve leakage current measurement from 0.01uA to 300uA and partial discharge measurement from 1pC to 100000 pC, which can meet the product quality testing needs of most integrated isolation devices and high insulation materials.
The Main Technical Parameters:
|
Output Voltage Range |
0.100kV~10.00kV |
|
Accuracy |
±(1% set value + 5 words) |
|
Resolution |
1V |
|
Voltage Rise Time |
0.3s~999.9s, 0=voltage rise time off |
|
Testing Time |
0.3s~999.9s, 0=continuous test |
|
Voltage Drop Time |
0.3s~999.9s, 0=voltage drop time off |
|
Intervals |
0.0s~999.9s, 0=interval time off |
|
General Specifications Correspond To Environmental Range |
18℃~28℃, ≤70%RH |
|
Output Waveform Distortion |
≤1% (at maximum voltage, no load or purely resistive load) |
|
Partial Discharge Meter |
Range: 1.0~100000pC Resolution: 0.01pC |
|
Accuracy |
1% indication +0.5pC |
|
PD Detection Delay Time |
0.0s~999.9s, 0=delay time off |
|
Output Frequency |
50Hz/60Hz±0.1%, sine wave |
|
Working Environment Scope |
0℃~40℃, 15%~95% RH @ ≤40℃ No condensation |
|
Storage Environment Range |
-10℃~50℃, ≤80%RH |
|
Input Power |
220Vac, 50/60Hz |