Applicable standards: National standard “GB4074.6”, IEC “60851”, Japanese industrial standard “JIS C3003”, American “NEMA MW 1000” standard & patented design
No mechanical weight required
Common to round and flat wires
Compatible with three standards: IEC, NEMA and JIS
Patented design
Common to round wire and flat wire
10-inch touch all-in-one computer
Can be equipped with QR code scanner and inductive trigger scanning
WIFI network support, detection results are automatically uploaded to the database or user MES system
All test data and spool product information can be automatically transmitted to the host computer, and automatically saved and analyzed by the “QME Enameled Wire Quality Management System”
Product Description:
Applicable standards: National standard “GB4074.6”, IEC “60851”, Japanese industrial standard “JIS C3003”, American “NEMA MW 1000” standard & patented design
No mechanical weight required
Common to round and flat wires
Compatible with three standards: IEC, NEMA and JIS
Patented design
Common to round wire and flat wire
10-inch touch all-in-one computer
Can be equipped with QR code scanner and inductive trigger scanning
WIFI network support, detection results are automatically uploaded to the database or user MES system
All test data and spool product information can be automatically transmitted to the host computer, and automatically saved and analyzed by the “QME Enameled Wire Quality Management System”
The Main Technical Parameters:
|
Enameled Round Wire with Nominal Diameter ≤5.000mm, Narrow Side ≤5mm Wide Side ≤12mm enameled flat wire |
|
|
Heating (Brass) Mold Dimensions |
(100×100×70)mm Error: ±1mm |
|
The Two Wire Troughs Of The Heating Mold Are Perpendicular To Each Other, And Their Intersection Angle |
90°±5° |
|
Maximum Test Temperature |
600℃ |
|
The Difference Between The Indicated Temperature And The Actual Temperature Of The Sample Cross Current |
≤2℃ |
|
Sensitivity |
IEC 5±0.5mA, JIS5±0.5mA, NEMA20±10mA |
|
Dimensions |
340×400×680 mm (L×W×H) |
|
Short Circuit Current Between Two Specimens |
≤50mA |
|
Test Voltage Between Two Specimens |
IEC AC(100±10)V, JIS AC(100±10)V, NEMA AC115V |
|
Timing Device |
1 second to 99 minutes and 59 seconds, Any setting. Error of timing device 120S: ± 2S |
|
Flat Wire Steel Ball Method Test Steel Ball |
1.6mm |
|
Flat Wire Steel Ball Method Test Weight |
1KG |
|
Input Power |
AC 220V±5% 50HZ |
|
Power Consumption |
≤1000W |
© Dongguan Zhongli Instrument Technology Co., Ltd.
Leave your inquiry, we will provide you with quality products and services!