Scope of application:
Suitable for low-voltage primary cables for ground vehicle electrical systems with rated DC voltage of 60V (AC 25V) or below.
Check the quality of the cable in normal use under the action of limited fluid and physical stress.
Compliant with standards:
Comply with EN 50618-2014, SAE J 1128-2005 test standard requirements.
Technical parameter:
Test method:
Strip a 25mm (1in) section of insulation from one end of a 900mm (36in) finished cable sample, and then lay the sample horizontally
The sample is tensioned but not stretched on a lever with a diameter of 3mm (1/8in). Adjust the balance weight so that when the weight is applied to a piece of machinery, the benefit is
There is no force acting on the sample at one end of the lever of 10 before. Then increase the applied weight continuously at a speed of 2.3kg/min (51b/min) to achieve
An ever-increasing force acts on the sample through the steel drill. At the moment when the insulation is cut through, a 3mm (1/8in) lever will contact the conductor and test
It just stopped. At this time, the weight applied should be recorded. After each degree of reading, the sample should move about 50mm (2in) and rotate 90° clockwise. Every
Four readings should be taken for each sample, and the average value is defined as the cut-through resistance of the tested cable.