Instrument Introduction:
The Differential scanning calorimetry (DSC) technique has been widely used. The differential scanning calorimeter is both a routine quality test tool and a research tool. Measmeasures the temperature, heat flow associated with the thermal transition inside the material. Our instrument is a heat flow type differential scanning calorimeter, with good repetition and high accuracy, which is especially suitable for accurate measurement of specific heat. The equipment is easy to calibrate, uses a low melting point, is fast and reliable, and has a very wide range of applications, especially in material research and development, performance testing and quality control. The properties of materials, such as glass transition temperature, cold crystallization, phase transition, melting, crystallization, product stability, curing / crosslinking, oxidation induction period, etc., are the research fields of differential scanning calorimetry, and different models are selected according to the experimental parameters and experimental requirements.
The application scope of differential scanning calorimeter is: curing reaction temperature and thermal effect of polymer materials, material phase transition temperature and thermal effect measurement, crystallization of polymer materials, melting temperature and thermal effect measurement, glass transition temperature of polymer materials, etc.
The sample and parameters were placed into the crucible separately and placed in the furnace for programmed heating to change the temperature of the sample and parameters. If the heat capacity of the reference and the sample are the same, and the sample has no heat effect, the temperature difference is almost “zero”, and a smooth curve is obtained. As the temperature increases, the sample has a thermal effect, and the parameter does not produce a thermal effect, the temperature difference between the two, in the DSC curve, the larger the temperature difference, the greater the temperature difference changes, the more the number of peaks. Peak up are called exothermic and peaks down are called heat absorption.
Instrument Characteristics:
New furnace structure, better resolution, resolution and baseline stability.
instrument offline computer data real-time transmission, interface friendly, easy to operate.
| Model | ZL-3047A |
| DSC | Differential Scanning Calorimeter |
| DSC Range | 0~±600mW |
| Temperature Range | Room temperature ~ 600℃ |
| Heat-Up Rate | 0.1~100℃ /min |
| Temperature Resolution | 0.01℃ |
| Temperature Fluctuations | ±0.01℃ |
| Temperature Reproducibility | ±0.1℃ |
| DSC Accuracy | 0.01mW |
| DSC Sensitivity | 0.001mW |
| Temperature Control Method | Heating up and constant temperature (automatic control of the whole program) |
| Curve Scan | Heating up the scan |
| Air Control | The instrument switches automatically |
| Display Mode | The 24bit color 7-inch LCD touchscreen display is shown |
| Data Interface | Standard USB interface |
| Instrument Standards | Equipped with standard substances (tin), the user can correct the temperature and thermal enthalpy |
| Note | All technical indicators can be adjusted according to the user needs |