1.standard:
•Implementation Standard: IEC60851-5
2.intrduce:
•It is made up of DC low resistance tester and DC resistance test clamp, and the latter has the function of sample alignment.
•LCD screen can display all the parameters and test results, and choose test lever according to sample’s resistance automatically.
•If you set current temperature, it will commute the test results into 20℃ resistance.
•It has two types of test clamps: electric potential clamps and current clamps, and equipped with sample calibration device.
•It is applicable to test copper and aluminum wires with conductor nominal diameters less than 8.0mm.
•You can test other conductor’s resistance with clamps.
3.parameters:
Test Length(Distance between the two electric potential clamps) |
(1000±1)mm |
Distance Between Electric Potential Clamp and Current Clamp) |
50mm |
Blade Width of Electric Potential Clamps |
≤2mm |
Error of Testing Length |
±0.1mm |
Analyzing Degree |
10μΩ |
Testing Range |
10μΩ-20KΩ |
Precision Class |
Four valid digits |
Precision(20±5℃) |
≤±0.2% |
Input Power Supply |
AC220V±10% 50Hz |
Consumed Power |
≤60W |
Dimension |
L×W×H 1350×260×300mm |
Weight |
27Kg |