Thermoplastic Cut-Through Tester
1.standard:
•Implementation standard: IEC60851-6
•It refers to the standards of NEMA and JIS.
2.introduce:
•It is applied to test round enameled and filmed wires with conductor nominal diameters from 0.1mm to 2.5mm.
•It supplies two test methods: heated method and constant temperature method.
•When the sample is cut through, the tester will discharge load and give an alarm automatically and display test time and temperature.
•It forces axial-flow fan to cool tester automatically so that the second test can be carried out quickly without long-time waiting.
• All the testing data and the sample characteristics value can be transfer to computer automatically, the MPS6 enameled wire quality data managerment system can save and analysis these data.
• The LCD screen can indicate the testing steps and display the testing result.
3.parameters:
Dimension of Heating Mould |
100×100×70mm |
Test Voltage Between Two Samples |
AC100±10V |
Cutting- through Current |
5±0.5mA |
Short-Circuit Current Between Samples |
<50mA |
Error Between the Displayed Temperature and the Sample’s Temperature |
<2℃ |
Test or Preheating Time |
1” ~ 99'59” predetermined |
Included Angle Between Heating Mould’s Two Winding Slots |
90° |
120 Seconds Error Allowance of Timing Device |
±2s |
Highest Test Temperature |
≤500℃ |
Test Temperature of Constant Temperature Method |
room temperature to 500℃ preset |
Input Power Supply |
AC220V±10% 50Hz |
Heating Power |
750W |
Dimension |
L×W×H 520×320×500 mm |
Weight |
35Kg |